Location:PRODUCTS >> Flame arrester and breathing valve >> Corrugated flame arrester
Corrugated flame arrester
Model: ZGB-1
Nominal diameter: DN50 ~ 300mm (2 "~ 12")
Nominal pressure: PN0.6 ~ 5.0MPa
Working temperature: ≤480 ℃ The
Main material: carbon steel WCB, stainless steel 304,316
Applicable medium: A type, oil, liquefied hydroxide type, kerosene, Diesel oil, a stupid, crude oil
Connection: flange connection (II) thread connection (III) male thread (IV)
Design standards: GB5908-86, GB1347-92
Flange standard: HG 20592-97, ANSI B 1.6, GB HGJ SH JB

ZGB-1 corrugated flame arrester Overview:
This product is widely used in oil storage tanks, is to prevent accidental fire invade the tank, to prevent accidents, is the ideal product for tank fire. 

ZGB-1 Corrugated flame arrester performance and features:

• The flame arrester has the advantages of reasonable structure, light weight, corrosion resistance and explosion-proof performance, and can withstand fire for 13 times in a row with a subsonic flame test. 
Flame arrester easy to repair, easy to install, do not check when removing the breathing valve. Resistance to burning qualified, resistant to burning test 1 hour without tempering. 
• The flame arrester core is stainless steel, corrosion-resistant and easy to clean. Shell hydraulic test qualified.

ZGB-1 corrugated flame arrester Scope:
The flame arrester is suitable for pipes, flash point of less than 28 ℃ Class A, oil, hydrogenated liquefied and flash point of less than 60 ℃ of kerosene, diesel, a stupid, crude oil And so on, can be used with the respiratory valve supporting the use, but also can be used alone, within the floating roof tank vent, gas tank on the ground floor gas tank. 
 
Corrugated flame arrester repair and maintenance:
In order to ensure the performance of flame arrester to achieve the purpose of safe use, flame arresters should be regularly checked and maintained. 
 • Flame arresters are inspected semi-annually to check if the fire barrier core is clogged, deformed, etched. 
 • It is found that the plugged flame barrier core should be cleaned to ensure that each hole in the core is clear and that the fire barrier should be replaced for deformation and corrosion. 
 • When reinstalling the flame retardant core, ensure that the joint surface is tight and leakproof.

Corrugated flame arrester parts material:

Body material Carbon steel WCB, stainless steel 304,316
Fire retardant core material Stainless steel explosion-proof corrugated plate
Sealing material Asbestos rubber, PTFE PTFE
Ambient temperature ℃ ≤480
Nominal pressure (MPa) 0.6 ~ 5.0
Explosion-proof level BS5501: Ⅱ A, Ⅱ B, Ⅱ C


+86-21-69755272
qrCode
主站蜘蛛池模板: 亚洲天堂三级 | 一二三四免费手机在线观看视频 | 国产美女在线观看 | 亚州毛色毛片免费观看 | 国产成人精品一区二区免费视频 | 日本a v 黄| 亚洲伊人久久大香线蕉苏妲己 | 2021国产精品视频 | 青草青草久热精品观看 | 日本免费第一区二区三区 | 色在线视频 | 亚洲刺激视频 | 日本三级欧美三级香港黄 | 成人区在线观看免费视频 | 一个色综合久久 | 午夜激情福利网 | 日本啪啪片 | 免费的两性视频网站 | 日韩色视频一区二区三区亚洲 | 午夜免费观看_视频在线观看 | 日本高清乱码中文字幕 | 一级特级aaaa毛片免费观看 | 日美一级毛片 | 天天做天天爱天天怼 | 日本一级特黄特色大片免费视频 | 国产亚洲图片 | 欧美黄色网页 | 经典三级久久久久 | 欧美在线视频免费观看 | 三级在线视频 | 欧美18videossex性欧美 | 午夜影视在线视频观看免费 | 日本a级毛片免费视频播放 日本a级毛片视频播放 | 日韩a视频 | 狠狠五月 | 日韩美女一级毛片 | 日韩在线视频播放 | 亚洲综合色婷婷 | 日韩一级伦理片 | 国内视频一区二区三区 | 欧美日韩亚洲区久久综合 |